No arrival time is promisedCorsica, SD 57328
Call (833) 751-2102
(833) 751-2102
Serving Douglas County

Flashing Repair at Chimneys, Walls and Vents in Corsica

Rebuilding the metal joints where a roof meets a wall, a chimney, a vent or another slope, so water is shed rather than sealed.

  • Hail and wind roof inspections
  • Storm tarping and leak repair
  • Corsica and Douglas County

Get a fast quote

Fastest: call (833) 751-2102. Or send this and we call you back.

Flashing repair

Flashing repair: what it covers

Quick answer

Flashing is the metal that carries water across the places a roof cannot simply cover: walls, chimneys, vents, valleys and edges. Repair means opening the courses, replacing or re-laying the metal in the right order of overlap, and closing it back up. Sealant is a finish, never the mechanism.

Flashing repair illustration for Corsica, SD

Every roof leak has a shape, and the ones that start at flashing have a particular one. The water appears somewhere specific and repeatable, often only in certain weather, often far enough from the joint that nobody suspects the joint. That is the nature of a metal detail: it does not fail across an area, it fails at a line, and the line directs water somewhere.

Three different kinds of load work on these joints in this part of South Dakota, and they are worth naming separately because they fail metal in different ways. Hail dents and chips it from above. Wind drives rain sideways and uphill against the vertical leg. Meltwater sitting behind ice at the eave pushes water backwards under laps that were only ever designed to shed what runs down.

A flashing repair is therefore a repair to a water path rather than to a piece of metal. The question is never only whether the metal is sound; it is whether each piece still overlaps the piece below it in the direction the water is traveling. Where it does not, new metal in the same wrong order will leak the same way. Call (833) 751-2102 and say where the water is showing.

Service area
Corsica & Douglas County
Availability
No arrival time is promised
Warning signs

Signs you need flashing repair

Flashing work happens at the awkward places on a roof: beside a chimney, in a valley, against a wall, at the edge. Those are the spots with the least secure footing and the shortest distance to a fall. Cut metal edges are sharp enough to do real damage through a glove. Do not go up to investigate, and in particular do not add another layer of sealant to a joint that has already been sealed, because it hides what is happening and makes the eventual repair bigger. Look for stains inside, note which weather brings them, and have the joint opened properly.

  • A stain on a ceiling or a wall that only grows when rain comes in on the wind
  • Metal at a wall or a chimney standing away from the surface instead of lying tight
  • Hardened, cracked sealant along a joint, or several layers of it built up over years
  • Rust streaks running down from a vent, a flue or a valley
  • A dent or a chipped painted surface on a vent hood, drip edge or valley metal after hail
  • A plastic pipe collar split around the pipe where the sun has worked on it
  • Damp or spalling brick, or a damp patch inside a wall, below where the roof meets it
  • Water showing at the ceiling several feet from any joint, after snow has sat on the eave
Our process

How our flashing repair visit works

  1. The water path worked out before any metal is touched

    Where water appears inside is where it arrived, not where it entered. The joints above the stain are examined, the direction of flow across the roof is read, and the weather the leak appears in is taken into account, because a leak only in wind-driven rain points to a vertical leg and a leak only after snow points to the eave.

  2. Worn out, or built wrong, decided honestly

    A joint that was built correctly and has corroded or split needs like-for-like replacement. A joint that was never lapped correctly, or has a missing kickout, or was made with sealant instead of metal, needs rebuilding differently from how it was found. These are different jobs and the difference is explained before work starts.

  3. The courses opened rather than the surface sealed

    Shingles or panels around the joint are lifted so the metal underneath can be seen and reached. This is the step that separates a repair from a cosmetic fix, and it is the reason a proper flashing repair takes longer than running a bead along the top of the problem.

  4. Metal laid in the order water travels

    Each piece is set so the one above overlaps the one below, with the vertical leg carried high enough up the wall or chimney, and the counter flashing or siding brought back over it. Where a kickout is needed to throw water out onto the roof instead of into a wall, one is fitted. Fasteners go where water will not find them.

  5. Closed up, tested, and the damage behind it assessed

    The covering is reinstated, the detail is wetted and watched, and the sheathing and framing that the leak has already been soaking are checked. A leak that ran for a season leaves wet wood, and saying so is part of the job even when it enlarges it.

Job stories

Typical jobs for flashing repair

Typical job
Illustration: A stain beside a chimney that only shows in driving rain

A stain beside a chimney that only shows in driving rain

What homeowners notice
A damp patch appears on a wall beside the chimney, but only when rain comes in on the wind. The shingles around the chimney look sound and have never been disturbed.
What we do
Water is traced from the attic to the chimney's upslope side, where old sealant has hardened and cracked and the counterflashing has pulled away from the masonry joint. Step flashing is replaced in overlapping layers and the counterflashing is reseated into the joint rather than sealed over.
What to expect
The damp patch fades over the weeks that follow, and photographs of the new metal go into the owners' file.

Half a day typical visit

Which way is the water moving when a joint leaks?

Down, sideways or backwards, and the three have different causes. Water running down defeats a bad lap; water driven sideways gets behind a short vertical leg; water backed up behind ice travels uphill under the metal.

Getting this right is most of the diagnosis. A leak that only shows in heavy straight rain usually means a lap or a fastener. A leak that only shows when rain arrives on the wind means the vertical leg is too short, or the counter flashing is not covering it, or there is no kickout where a roof dies into a wall. A leak that shows after snow, in no rain at all, is meltwater moving uphill under the laps.

Each of those is fixed differently, which is why the weather the leak appears in is asked about at the start. Fixing a wind-driven leak as if it were a lap failure produces a repair that holds all summer and comes back with the first storm that arrives from the wrong direction.

Why does the metal give out before the covering does?

Because it is doing the hardest work on the roof. Joints concentrate water that an entire slope has collected, they sit against materials that move at a different rate, and they are where every other trade's penetrations land.

An open slope sheds water thinly and evenly. A valley takes everything two slopes gathered and runs it in a narrow channel. A wall junction has a roof expanding and contracting against a wall that does not. A chimney is a separate structure passing through the plane of the roof, settling on its own schedule. The metal at those places absorbs all of that movement.

Add to that the fact that flashing is usually the part of a roof that is reused. Covering gets replaced and the old metal is left in place to save a step, so a roof can have new shingles over joints that were tired when the last ones went on. When a reroof is being scoped, roof replacement should say explicitly which metal is being renewed.

What is a kickout and why is it worth a paragraph?

It is a small turned-out piece at the lowest end of a wall flashing that throws water onto the roof instead of behind the siding. Its absence is one of the most damaging small omissions in roofing.

Where a roof slope runs down and dies into a wall, everything that slope collected arrives at that one point. Without a piece to divert it outward, the water goes straight down behind the cladding and into the wall cavity, where it is invisible for years. The roof above it can be in good condition throughout.

The symptom is usually interior: damp at the top of a wall, a stain that does not line up with anything on the roof, or paint failing inside. Fitting the missing piece is a modest repair. Finding what the missing piece has already done to the wall is sometimes not, and an honest scope says so rather than fitting the metal and walking away.

What decides the size of a flashing repair?

How many joints are involved, how much covering has to be lifted to reach them, whether the detail is being copied or rebuilt, roof pitch and access, and the condition of the wood behind. No figure is published; the price is explained and approved before work begins.

A single pipe collar on a low slope is at one end of the range. A chimney where the counter flashing has to be cut back in, the step flashing renewed and a cricket formed, on a steep roof, is at the other. Rebuilding a detail that was wrong costs more than replacing one that was right, because more of the surrounding roof has to come up.

The hidden variable is wet sheathing. A joint that has leaked for years has usually been feeding the same patch of wood, and soft wood will not hold the fasteners the new metal needs. That is found by opening the joint, which is why nothing is quoted before the roof is seen and no arrival time is promised.

Does a flashing leak need to go through insurance?

Often not, because wear is not an event. Where hail or wind damaged the metal, the Division of Insurance's claims guidance applies in the usual way: document the damage before repairs and keep the damaged material.

Flashing that has corroded or opened with age is maintenance, and most policies treat it that way. Flashing dented by hail or torn off by wind on a dated storm is damage, and the Division of Insurance advises photographing or filming it before repairs, keeping the damaged property for the adjuster, and asking for an itemized explanation of any settlement offer. It also warns that a claim may be denied if permanent repairs are made before the damage has been inspected.

If a storm is in question, a hail damage roof inspection records the metal alongside everything else and dates it to the event. If no storm is involved, there is nothing to claim and the repair is simply booked.

Options

Types and options for flashing repair

A joint that was built right and has worn out

Metal corrodes, fasteners back out, laps open as a building moves, and plastic collars around pipes go brittle and split. This is the straightforward case: the detail was correct, so the replacement copies it in sound material. Age shows up first on the smallest components, which is why a pipe collar is a common first repair on a roof that is otherwise fine. The work is local and the rest of the covering is left alone.

A joint that was wrong from the day it was built

Step flashing missing and replaced with a continuous strip, a wall-to-roof junction with no kickout so water runs into the siding, counter flashing bedded into nothing, a valley with laps running the wrong way. These leak from new and get sealed repeatedly rather than fixed. Rebuilding them means doing something different from what was there, which is why the explanation matters more than usual before the work starts.

Soft metal that hail has worked on

Hail dents and chips the metal at the edges, the valleys and the vent hoods, and the protective coating goes before the metal does. On June 13, 2017 NWS Sioux Falls logged 1-inch hail 7 miles west of Harrison and 1-inch hail with a 70 mph gust 5 miles west-northwest of Delmont. Damage like that often leaves the shingles arguable and the metal plainly marked, so flashing and edge metal are frequently the clearest evidence on the roof as well as a genuine repair item.

Flashing on a metal or farm building roof

Panel roofs on shops, barns and machine sheds have their own set of joints: ridge closures, gable and eave trim, transitions where a lean-to meets a main span, and boots where pipes come through. These fail at fasteners and closures more than in the middle of a panel, and wind finds a loose trim edge quickly. Metal roofing and farm building roofing cover the wider work on those buildings.

Douglas County

Why flashing repair is different in South-central South Dakota

Corsica is a town of 561 people with 279 housing units counted in 2020, laid out in 1905 and named for the native land of some of the railroad workers who built through here. Houses that size and age carry the full set of joints anyway: a flue, a vent or two, a porch roof dying into a wall, a dormer or a lean-to added at some point. The smallest house in town can have the most troublesome flashing detail on it.

The sourced weather here puts pressure on the vertical leg of a joint rather than on the open slope. NWS Sioux Falls recorded a 74 mph gust at 6:20 pm and a 77 mph gust at 6:25 pm on July 15, 2025 at a Mesonet station 3 miles south of Corsica, and 1-inch hail with a 70 mph gust 5 miles west-northwest of Delmont on June 13, 2017. Rain arriving with wind like that does not fall onto a roof, it is pushed at it, and a short flashing leg or a missing counter flashing is where it gets in.

Winter adds the opposite problem on the same metal. Heat escaping a house melts snow on the roof, the meltwater refreezes at the cold eave, and water backs up behind the ice and under the laps, moving uphill in a way no flashing detail is designed to resist. That is why eave metal, valley bottoms and the lower end of a wall flashing are checked after a hard winter and not only after a storm. Ice dam roof repair deals with the cause.

Still stuck? Tell us what is happening.

Call and someone will take the details and say what can be scheduled. For non-urgent flashing repair, send the form and we'll call you back.

Related

Roof leak repair

Leak work on houses and farm buildings around Corsica, worked backward along the water's path rather than forward from the stain.

Roof repair

Repair work on houses, shops and farm buildings around Corsica, scoped from which layer of the roof actually failed.

Ice dam roof repair

Repairing the eave an ice dam has damaged, then finding and closing the heat path that made the ice form in the first place.

Attic ventilation

Intake and exhaust ventilation, baffles and air sealing on Corsica-area houses, aimed at the heat loss that causes eave ice and attic damp.

FAQ

Flashing repair FAQs

How do I know it is the flashing and not the shingles?

The pattern usually tells you. A flashing leak appears in the same place every time and is tied to a feature of the roof: a chimney, a vent, a valley, a wall. A covering leak tends to move about and follow the general condition of the roof. The weather matters too: a leak only in wind-driven rain, or only after snow has sat on the eave, points at a joint. Either way the stain is below where the water arrived, not below where it entered.

I sealed it last spring and it is leaking again. Why?

Because sealant is a finish, not the water path. It fills a gap it cannot see the shape of, hardens, cracks with the movement of the joint, and then holds water in the gap instead of out. A joint that needs sealing to work was built wrong or has worn out, and the cure is metal lapped in the right order. Repeated sealing also makes the real repair bigger, since the hardened layers have to come off before anything can be laid properly.

Can the flashing be replaced without disturbing the shingles?

Not properly. Flashing sits under the courses by design, so reaching it means lifting them, which is exactly what a surface fix avoids and why surface fixes do not last. On a sound roof the shingles come up and go back with little trouble. On a brittle covering some of them will break during the work, and that is said before starting rather than discovered after.

The chimney has leaked for years and nobody has fixed it. Is it hopeless?

No, but it may be bigger than a flashing job. A chimney is a separate structure passing through the roof plane, and a long-standing leak around one has usually wet the sheathing and sometimes the framing beside it. The repair is to cut counter flashing properly into the masonry, renew the step flashing up both sides, and form a cricket where the chimney is wide enough to need one. What the water already did behind it is assessed at the same time.

Does hail damage flashing or just shingles?

It damages both, and the metal is often the clearer evidence. Hail dents gutters, drip edge, valley metal and vent hoods, and chips the coating off so the bare metal starts to corrode. NWS Sioux Falls logged 1-inch hail west of Harrison and west-northwest of Delmont on June 13, 2017. Dents in soft metal are harder to mistake for age than bruises on asphalt, which is why they are recorded carefully in an inspection.

Should flashing be renewed when the roof is replaced?

In almost every case, yes, and it should be stated in the scope either way. Reusing old metal under a new covering is the standard shortcut, and it produces a roof with a new surface over joints that were already tired. If a quote does not say which flashings are being renewed, that is a reasonable question to put, and the state's consumer protection office advises getting written quotes naming the business and comparing bids.

Can a wall leak from the roof damage the wall itself?

Yes, and this is the main reason the small missing pieces matter. Water diverted behind cladding instead of out onto the roof runs down inside a cavity where nothing dries it and nobody sees it. It can show up as damp at the top of a wall, failing paint inside, or soft sheathing found later during other work. Fixing the roof detail stops the supply; what has already been wet has to be looked at separately.

WhatsApp